How it fits on your pipe
Scroll to install an actuator valve, connect the Main Unit+ and test the system. The model is simplified and not to scale.

Step 1 of 8
Start at the water main
The actuator valve goes on the incoming supply pipe, so it can stop water to the whole property. Find the main stopcock where the supply enters.
Step 2 of 8
Choose the position
Fit the valve downstream of the main stopcock and any pressure-reducing valve, on a straight run with room for the actuator and the manual wheel above it.
Step 3 of 8
Shut off, drain and cut in
Close the stopcock and drain the line. Remove a section of pipe to suit the valve body, using fittings that match your pipe and local plumbing code.
Installation should be carried out by a qualified plumber.
Step 4 of 8
Fit the valve
Seat the valve with the flow arrow pointing downstream and tighten the threaded connections. Brass bodies are for drinking water; choose bronze for flushing or sea water.
Step 5 of 8
Connect the Main Unit+
Mount the Main Unit+ on a wall nearby and plug in the valve cable. Need more distance? Add the 5 m valve extension. Power it from the 12 V supply.
Step 6 of 8
Place the sensors
Put a NEW End Unit wherever water would collect first: under sinks, behind the washing machine, beside the water heater. Each Main Unit+ takes up to 10.
Step 7 of 8
Open the water and test
Reopen the stopcock and put a little water on a sensor. The Main Unit+ sounds the alarm and the valve closes the supply. With a gateway, the app gets the alert too.
Step 8 of 8
It keeps itself ready
Every 5 days the control unit turns the valve to keep it moving freely, without interrupting your water. Below 4 °C it closes the valve to protect the pipes.
Before you start
Have these ready, or send us the details and we will specify the kit for you.
- Valve size
- Match the valve to the supply pipe: DN15 (½″) to DN50 (2″).
- Valve body
- Brass for drinking water. Bronze for flushing or sea water.
- Fittings
- Connectors to suit your pipe material, to local plumbing code.
- Power
- A mains socket within reach of the Main Unit+ for its 12 V supply.
- Cable run
- Up to the supplied valve cable, or add the 5 m valve extension.
- For app alerts
- A 2.4 GHz Wi-Fi network where the gateway will sit.